Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 106
Filtrar
1.
J Orthop ; 53: 140-146, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38601894

RESUMO

Introduction: Although gluteal tears have been observed in a substantial percentage of total hip arthroplasty (THA) patients and hip osteoarthritis (OA) has been shown to alter the function of the gluteal muscles, the association between gluteal tears and hip OA has not been characterized. Therefore, we evaluated (1) the overlap between hip OA and gluteal tears, (2) the relative risks of gluteal tears in patients who have hip OA, and (3) gluteal tear-free survival after diagnosis or treatment for hip osteoarthritis. Methods: This retrospective study sourced data from TriNetX, a research network that aggregates data from over 92 million patients. Relative risks for gluteal tears were calculated for known risk factors for gluteal tears, age ≥45 years, female sex, and obesity, as well as for hip OA, hip injections, and THA. A subgroup analysis was performed utilizing a Cox proportional hazard model for patients who were diagnosed with hip OA, received a hip injection, or underwent THA in 2015 to assess gluteal tear-free survival over a 9-year timeframe. Results: There was a large degree of overlap between patients with hip OA and gluteal tears, as 17.9% of patients with hip OA and 27.5% of patients with a gluteal tear also had the other pathology. Hip OA was associated with a markedly increased risk of a gluteal tear compared to healthy controls (Relative risk: 26.75, 95% CI: 26.64-26.86). Upon controlling for the established risk factors of gluteal tears, patients with hip OA had a markedly more likely to subsequently be diagnosed with an abductor tear (Hazard ratio: 12.46, 95% CI: 11.75-13.22). Conclusion: Overall, these findings suggest a strong association between hip OA and the development of gluteal tears, in which further investigation is merited to determine the biomechanical pathophysiology underlying this potential relationship to inform prevention and treatment strategies.

2.
J Robot Surg ; 18(1): 160, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38578350

RESUMO

Robotic assisted (RA) total hip arthroplasty (THA) offers improved acetabular component placement and radiographic outcomes, but inconsistent assessment methods of its learning curves render the evaluation of adopting novel platforms challenging. Therefore, we conducted a systematic review to assess the learning curve associated with RA-THA, both tracking a surgeon's performance across initial cases and comparing their performance to manual THA (M-THA). PubMed, MEDLINE, EBSCOhost, and Google Scholar were searched on June 16, 2023, to identify studies published between January 1, 2000 and June 16, 2023 (PROSPERO registration: CRD42023437339). The query yielded 655 unique articles, which were screened for eligibility. The final analysis included 11 articles, evaluating 1351 THA procedures. Risk of bias was assessed via the Methodological Index for Nonrandomized Studies (MINORS) tool. The mean MINORS score was 21.3 ± 0.9. RA-THA provided immediate improvements in acetabular component placement accuracy and radiographic outcomes compared to M-THA, with little to no experience required to achieve peak proficiency. A modest learning curve (12-17 cases) was associated with operative time, which was elevated compared to M-THA (+ 9-13 min). RA-THA offers immediate advantages to M-THA for component placement accuracy and radiographic outcomes. Surgeons should expect to experience increased operative times, which become less pronounced or equivalent to M-THA after a modest caseload.


Assuntos
Artroplastia de Quadril , Procedimentos Cirúrgicos Robóticos , Cirurgia Assistida por Computador , Humanos , Artroplastia de Quadril/métodos , Curva de Aprendizado , Procedimentos Cirúrgicos Robóticos/métodos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Cirurgia Assistida por Computador/métodos
3.
J Robot Surg ; 18(1): 104, 2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38430388

RESUMO

PURPOSE: Computer-navigated (CN) total hip arthroplasty (THA) offers improved acetabular component placement and radiographic outcomes, but inconsistent assessment methods of its learning curves render the evaluation of adopting a novel platform challenging. Therefore, we conducted a systematic review to assess the learning curve associated with CN-THA, both tracking a surgeon's performance across initial cases and comparing their performance to manual THA (M-THA). METHODS: A search was conducted using PubMed, MEDLINE, EBSCOhost, and Google Scholar on June 16, 2023 to find research articles published after January 1, 2000 (PROSPERO registration: CRD4202339403) that investigated the learning curve associated with CN-THA. 655 distinct articles were retrieved and subsequently screened for eligibility. In the final analysis, nine publications totaling 847 THAs were evaluated. The Methodological Index for Nonrandomized Studies (MINORS) tool was utilized to evaluate the potential for bias, with the mean MINORS score of 21.3 ± 1.2. RESULTS: CN-THA showed early advantages to M-THA for component placement accuracy and radiographic outcomes but longer operative times (+ 3- 20 min). There was a learning curve required to achieve peak proficiency in these metrics, though mixed methodologies made the required caseload unclear. CONCLUSIONS: CN-THA offers immediate advantages to M-THA for component placement accuracy and radiographic outcomes, though CN-THA's advantages become more pronounced with experience. Surgeons should anticipate longer operative times during the learning curve for CN-THA, which lessen following a modest caseload. A more thorough evaluation of novel computer-navigated technologies would be enhanced by adopting a more uniform method of defining learning curves for outcomes of interest. Registration PROSPERO registration of the study protocol: CRD42023394031, 27 June 2023.


Assuntos
Artroplastia de Quadril , Procedimentos Cirúrgicos Robóticos , Humanos , Artroplastia de Quadril/métodos , Curva de Aprendizado , Procedimentos Cirúrgicos Robóticos/métodos , Resultado do Tratamento , Computadores
4.
Bone Jt Open ; 5(3): 154-161, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38423101

RESUMO

Aims: It is important to analyze objectively the hammering sound in cup press-fit technique in total hip arthroplasty (THA) in order to better understand the change of the sound during impaction. We hypothesized that a specific characteristic would present in a hammering sound with successful fixation. We designed the study to quantitatively investigate the acoustic characteristics during cementless cup impaction in THA. Methods: In 52 THAs performed between November 2018 and April 2022, the acoustic parameters of the hammering sound of 224 impacts of successful press-fit fixation, and 55 impacts of unsuccessful press-fit fixation, were analyzed. The successful fixation was defined if the following two criteria were met: 1) intraoperatively, the stability of the cup was retained after manual application of the torque test; and 2) at one month postoperatively, the cup showed no translation on radiograph. Each hammering sound was converted to sound pressures in 24 frequency bands by fast Fourier transform analysis. Basic patient characteristics were assessed as potential contributors to the hammering sound. Results: The median sound pressure (SP) of successful fixation at 0.5 to 1.0 kHz was higher than that of unsuccessful fixation (0.0694 (interquartile range (IQR) 0.04721 to 0.09576) vs 0.05425 (IQR 0.03047 to 0.06803), p < 0.001). The median SP of successful fixation at 3.5 to 4.0 kHz and 4.0 to 4.5 kHz was lower than that of unsuccessful fixation (0.0812 (IQR 0.05631 to 0.01161) vs 0.1233 (IQR 0.0730 to 0.1449), p < 0.001; and 0.0891 (IQR 0.0526 to 0.0891) vs 0.0885 (IQR 0.0716 to 0.1048); p < 0.001, respectively). There was a statistically significant positive relationship between body weight and SP at 0.5 to 1.0 kHz (p < 0.001). Multivariate analyses indicated that the SP at 0.5 to 1.0 kHz and 3.5 to 4.0 kHz was independently associated with the successful fixation. Conclusion: The frequency bands of 0.5 to 1.0 and 3.5 to 4.0 kHz were the key to distinguish the sound characteristics between successful and unsuccessful press-fit cup fixation.

5.
Int Orthop ; 48(4): 1089-1096, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38332113

RESUMO

PURPOSE: Although rare, non-metastatic proximal femoral fracture (PFF) can develop in patients with active cancer. However, little data are available regarding the risks and benefits of surgical treatment in such patients. The purpose of his study was to investigate the risks and benefits of surgical treatment of PFF in patients with and without cancer. METHODS: We retrospectively examined the medical records of all patients treated for PFF, excluding those with pathological fracture, at our hospital from July 2013 to December 2020. The patients were divided into two groups; The active cancer group and the standard group. We investigated in both groups about surgical and medical complications during the perioperative period, walking ability two weeks postoperatively, and one-year postoperative mortality rate. RESULT: After the inclusion and exclusion criteria, 39 patients in the active cancer group and 331 patients in the standard group were finally investigated. There were no statistically significant differences between the two groups. The complication rate did not appear statistical significance between two groups (16.7% in active cancer group vs 10.7% in standard group: p = 0.272). Walking ability was also similar in two groups. Mortality rate at one year was significantly higher in the active cancer group. (41.2% in active cancer group vs 6.0% in standard group: p < 0.05). CONCLUSION: Although the active cancer group had a higher mortality rate at one year, which was influenced by the prognosis of the cancer, the benefits of surgical intervention, such as regaining walking ability, were the same in patients with and without active cancer.


Assuntos
Artroplastia de Quadril , Fraturas Espontâneas , Fraturas do Quadril , Neoplasias , Humanos , Estudos Retrospectivos , Fraturas Espontâneas/cirurgia , Neoplasias/cirurgia
7.
Regen Ther ; 25: 61-67, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38077288

RESUMO

Introduction: Although numerous studies have reported outcomes with various conservative approaches for the iliopsoas impingement after total hip arthroplasty (THA), reports on the use of locoregional autologous platelet rich plasma (PRP) injections for the iliopsoas impingement after THA are lacking. This phase 1 study therefore aimed to investigate the safety and feasibility of locoregional PRP injection for iliopsoas impingement after THA. Materials and methods: Patients diagnosed with iliopsoas impingement after THA who met the criteria for participation (symptoms persisting for more than 3 months, aged 20 years or older, and unable to receive non-steroidal analgesic or anti-inflammatory drugs) were eligible to participate in this clinical study. The primary endpoint was observed adverse events including procedure-related pain, and the secondary endpoints included pain and functionality of the hip joint, that were assessed using the Western Ontario and McMaster Universities Arthritis Index, Japanese Hip Disease Evaluation Questionnaire, and Forgotten Joint Score-12. Results: Three patients were screened for eligibility, and 3 patients were finally included in this study. Two participants (patients 1 and 2; aged 66 and 65 years, respectively) were female. The third participant (patient 3; age 73 years) was male. All patients experienced adverse events; however, none were found to be serious. None of the patients experienced any infections, or intra- or post-operative symptoms of nerve damage, or subcutaneous haemorrhage owing to the administration of locoregional PRP. Although patient 2 showed almost complete resolution of the symptom, patient 1 and 3 demonstrated persistent groin pain after the injection. Conclusion: We demonstrated the results of preliminary phase 1 prospective observational clinical study that administration of locoregional PRP injections for iliopsoas impingement following THA is both, safe and feasible.

8.
Expert Rev Med Devices ; 20(12): 1079-1086, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37942898

RESUMO

INTRODUCTION: The direct anterior approach (DAA) has its origins in the first and oldest approach for hip replacement in the literature, but at the same time it would not be fanciful to suggest its increasing popularity as the latest approach for hip replacement procedures, especially among younger surgeons. However, in a geographical context, the DAA is not considered the major approach in most countries. Moreover, the term DAA encompasses numerous variations in terms of technique. AREAS COVERED: In this narrative review, we describe our recent experience of advances in the DAA in terms of improved techniques and devices, along with some of its disadvantages. Also, we express our perspective on its future application. EXPERT OPINIONS: The DAA is established as one of exemplary approaches to THA. The use of fluoroscopy, the traction table, and appropriate soft tissue management has become essential in the DAA for a safe and trouble-free procedure with adequate patient comfort. With the combination of recent technologies such as robotics, three-dimensional preoperative planning, and artificial intelligence (AI)-based surgeon assist systems, we can look forward to the DAA being performed more efficiently in the future.


Assuntos
Artroplastia de Quadril , Cirurgiões , Humanos , Inteligência Artificial , Tração , Estudos Retrospectivos
9.
Technol Health Care ; 2023 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-37980586

RESUMO

BACKGROUND: Robotic assistance in total hip arthroplasty (RA-THA) has been shown to minimize laterality-based differences in acetabular cup positioning. OBJECTIVE: To determine if the use of a novel, fluoroscopy-based RA-THA system mitigates differences in acetabular cup placement between left (L) and right (R) side hip procedures, when compared to manual, fluoroscopic-assisted technique. METHODS: We conducted a retrospective review of 106 consecutive mTHA (40 L/66 R) and 102 RA-THA (48 L/54 R) primary direct anterior approach procedures. All cases were performed by a single right-hand-dominant surgeon, for a pre-operative diagnosis of osteoarthritis, avascular necrosis, or rheumatoid arthritis. Outcomes included acetabular cup inclination and anteversion, and the proportion of cups within the Lewinnek safe-zone. RESULTS: The average inclination of mTHA L cases was smaller than that of mTHA R cases (41.10∘± 7.38 vs. 43.97∘± 6.27; p= 0.04). For RA-THA, L and R cup angles were similar. There were fewer overall mTHA hips within the Lewinnek safe-zone compared to RA-THA (0.59 vs. 0.78; p= 0.003), as well as fewer mTHA R cases than RA-THA R cases (0.59 vs. 0.80; p= 0.03) within safe zone. CONCLUSION: Use of a novel, fluoroscopy-based robotic system mitigates laterality-based differences in acetabular cup placement that were observed in a manual, fluoroscopic-assisted cohort.

10.
Technol Health Care ; 2023 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-37980587

RESUMO

BACKGROUND: Patient obesity is a risk factor for poor acetabular cup positioning in total hip arthroplasty (THA). OBJECTIVE: To assess the impact of using a novel, fluoroscopy-based robotic THA system on acetabular cup placement in obese versus non-obese patients. METHODS: A review of 105 consecutive manual unassisted (mTHA) (47 Obese/58 Non-obese) and 102 robotic-assisted (RA-THA) (50 Obese/52 Non-obese) primary, direct anterior approach THA procedures was conducted. All cases were performed by a single surgeon, for a pre-operative diagnosis of osteoarthritis, avascular necrosis, or rheumatoid arthritis. Obesity was defined as a Body Mass Index (BMI) ⩾ 30 kg/m2. Outcomes included acetabular cup inclination and anteversion, and the proportion of cups within the Lewinnek safe-zone. RESULTS: Obese patients in the mTHA cohort had larger cup inclination angles on average compared to non-obese patients (44.82∘± 6.51 vs. 41.39∘± 6.75; p= 0.009). Obese mTHA patients were less likely to have cup placement within the Lewinnek zone compared to non-obese mTHA patients (0.48 vs. 0.67; p= 0.027). Obesity had no effect on the accuracy of RA-THA. CONCLUSION: Obesity affects the placement of the acetabular component in manual THA. The novel, fluoroscopy-based robotic THA system in this study demonstrated accurate cup placement regardless of obesity status.

11.
Bone Joint J ; 105-B(12): 1252-1258, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38035608

RESUMO

Aims: Lateral femoral cutaneous nerve (LFCN) injury is a potential complication after the direct anterior approach for total hip arthroplasty (DAA-THA). The aim of this study was to determine how the location of the fasciotomy in DAA-THA affects LFCN injury. Methods: In this trial, 134 patients were randomized into a lateral fasciotomy (n = 67) or a conventional fasciotomy (n = 67) group. This study was a dual-centre, double-blind, prospective randomized controlled two-arm trial with parallel group design and a 1:1 allocation ratio. The primary endpoint was the presence of LFCN injury, which was determined by the presence of numbness, decreased sensation, tingling, jolt-like sensation, or pain over the lateral aspect of the thigh, excluding the surgical scar, using a patient-based questionnaire. The secondary endpoints were patient-reported outcome measures (PROMs) using the Western Ontario and McMaster Universities osteoarthritis index (WOMAC), Japanese Orthopaedic Association Hip Disease Evaluation Questionnaire (JHEQ), and the Forgotten Joint Score-12 (FJS-12). Assessments were obtained three months after surgery. Results: The incidence of LFCN injury tended to be lower in the lateral fasciotomy group (p = 0.089). In the lateral fasciotomy group, there were no significant differences in the mean PROM scores between patients with and without LFCN injury (FJS-12: 54.42 (SD 15.77) vs 65.06 (SD 26.14); p = 0.074; JHEQ: 55.21 (SD 12.10) vs 59.72 (SD 16.50); p = 0.288; WOMAC: 82.45 (SD 6.84) vs 84.40 (SD 17.91); p = 0.728). In the conventional fasciotomy group, there were significant differences in FJS-12 and JHEQ between patients with and without LFCN injury (FJS-12: 43.21 (SD 23.08) vs 67.28 (SD 20.47); p < 0.001; JHEQ: 49.52 (SD 13.97) vs 59.59 (SD 15.18); p = 0.012); however, there was no significant difference in WOMAC (76.63 (SD 16.81) vs 84.16 (SD 15.94); p = 0.107). Conclusion: The incidence of LFCN injury at three months after THA was comparable between the lateral and conventional fasciotomy groups. Further studies are needed to assess the long-term effects of these approaches.


Assuntos
Artroplastia de Quadril , Coxa da Perna , Humanos , Antivirais , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Fasciotomia , Nervo Femoral/lesões , Estudos Prospectivos , Coxa da Perna/inervação , Resultado do Tratamento
12.
Int J Med Robot ; : e2582, 2023 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-37776329

RESUMO

BACKGROUND: The purpose of this study was to assess the cost-effectiveness of a novel, fluoroscopy-based robotic-assisted total hip arthroplasty (RA-THA) system compared to a manual unassisted technique (mTHA) up to 5 years post-operatively. METHODS: A Markov model was constructed to compare the cost-effectiveness of RA-THA and mTHA. Cost-effectiveness was defined as an Incremental Cost-Effectiveness Ratio (ICER) <$50 000 or $100 000 per Quality Adjusted Life Year (QALY). RESULTS: RA-THA patients experienced lower costs compared to mTHA patients at 1 year ($20 865.12 ± 9897.52 vs. $21 660.86 ± 9909.15; p < 0.001) and 5 years ($23 124.57 ± 10 045.48 vs. $25 756.42 ± 10 091.84; p < 0.001) post-operatively. RA-THA patients also accrued more QALYs (1-year: 0.901 ± 0.117 vs. 0.888 ± 0.114; p < 0.001; 5-years: 4.455 ± 0.563 vs. 4.384 ± 0.537 p < 0.001). Overall, RA-THA was cost-effective (1-year ICER: $-61 210.77; 5-year ICER: $-37 068.31). CONCLUSIONS: The novel, fluoroscopy-based RA-THA system demonstrated cost-effectiveness when compared to manual unassisted THA.

13.
Arthroplast Today ; 21: 101136, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37193539

RESUMO

Background: Listening to the change in the hammering sound is 1 of the elements used to assess the cementless stem stability. This study aimed to quantitatively investigate the change in the acoustic characteristics between the early and late phases of cementless stem insertion in total hip arthroplasty and to identify which patient characteristics contribute to the change in the hammering sound. Methods: The acoustic parameters of the hammering sounds in the early and late phases of cementless taper-wedged stem insertion for 51 hips in 45 patients who underwent total hip arthroplasty (mean age = 68 years, height = 1.56 m, weight = 55.0 kg) were analyzed. Parameters including patient's basic characteristics, radiographical femoral morphology, and canal fill ratio were assessed as potential contributors to the change in the hammering sound. Results: The low-frequency bands (0.5-1.0 kHz and 1.0-1.5 kHz) showed the largest changes during stem insertion and were therefore considered key bands for the analysis of sound alterations. Multivariate linear regression analysis showed that height (ß = 8.312, P = .013) and proximal canal fill ratio (ß = -3.8568, P = .038) were independently associated with the sound alterations. The decision tree analysis identified height (≥1.66 m or <1.66 m) as the best single discriminator for the sound alteration. Conclusions: Patients with smaller stature showed the least change in the hammering sound during stem insertion. Understanding the acoustic characteristics of hammering sound alteration during cementless stem insertion may aid in the achievement of optimal stem insertion.

14.
Arthroplasty ; 5(1): 13, 2023 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-37020254

RESUMO

BACKGROUND: Although it is important to consider pelvic alignment and mobility in the standing and sitting positions before THA, it is not known how to preoperatively predict individual postoperative pelvic alignment and mobility. The purpose of this study was to investigate the pelvic alignment and mobility before and after THA, and to develop a predictive formula using preoperative factors to calculate postoperative sagittal alignment and mobility. METHODS: One hundred seventy patients were assessed. The 170 patients were randomly divided into a prediction model analysis group (n = 85) and an external validation group (n = 85). In the prediction model analysis group, preoperative spinopelvic parameters were used to develop the predictive formulas to predict the postoperative sacral slope (SS) in standing and sitting positions and ΔSS. These were applied to the external validation group and assessed. RESULTS: R2 in multiple linear regression models for postoperative SS in standing, SS in sitting and ΔSS were 0.810, 0.672, and 0.423, respectively. The values of predicted and postoperative parameters were very close with no significant difference: SS in standing (33.87 vs. 34.23, P = 0.834), SS in sitting (18.86 vs. 19.51, P = 0.228), and ΔSS (15.38 vs. 14.72, P = 0.619). CONCLUSION: The present study showed that the pelvic alignment and mobility after THA can be predicted using preoperative factors. Although a model with higher accuracy is needed, it is important to use a predictive formula to estimate the postoperative condition before performing THA.

15.
Int Orthop ; 47(7): 1689-1705, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37036496

RESUMO

PURPOSE: Several reports have identified prognostic factors for hip osteonecrosis treated with cell therapy, but no study investigated the accuracy of artificial intelligence method such as machine learning and artificial neural network (ANN) to predict the efficiency of the treatment. We determined the benefit of cell therapy compared with core decompression or natural evolution, and developed machine-learning algorithms for predicting ten year collapse-free survival in hip osteonecrosis treated with cell therapy. Using the best algorithm, we propose a calculator for "prognosis hip osteonecrosis cell therapy (PHOCT)" accessible for clinical use. METHODS: A total of 3145 patients with 5261 osteonecroses without collapses were included in this study, comprising 1321 (42%) men and 1824 (58%) women, with a median age of 34 (12-62) years. Cell therapy was the treatment for 3021 hips, core decompression alone for 1374 hips, while absence of treatment was the control group of 764 hips. First, logistic regression and binary logistic regression analysis were performed to compare results of the three groups at ten years. Then an artificial neural network model was developed for ten year collapse-free survival after cell therapy. The models' performances were compared. The algorithms were assessed by calibration, and performance, and with c-statistic as measure of discrimination. It ranges from 0.5 to 1.0, with 1.0 being perfect discrimination and 0.5 poor (no better than chance at making a prediction). RESULTS: Among the 3021 hips with cell therapy, 1964 hips (65%) were collapse-free survival at ten years, versus 453 (33%) among those 1374 treated with core decompression alone, and versus 115 (15%) among 764 hips with natural evolution. We analyzed factors influencing the prediction of collapse-free period with classical statistics and artificial intelligence among hips with cell therapy. After selecting variables, a machine learning algorithm created a prognosis osteonecrosis cell therapy calculator (POCT). This calculator proved to have good accuracy on validation in these series of 3021 hip osteonecroses treated with cell therapy. The algorithm had a c-statistic of 0.871 suggesting good-to-excellent discrimination when all the osteonecroses were mixed. The c-statistics were calculated separately for subpopulations of categorical osteonecroses. It retained good accuracy, but underestimated ten year survival in some subgroups, suggesting that specific calculators could be useful for some subgroups. This study highlights the importance of multimodal evaluation of patient parameters and shows the degree to which the outcome is modified by some decisions that are within a surgeon's control, as the number of cells to aspirate, the choice of injecting in both the osteonecrosis and the healthy bone, the choice between unilateral or bilateral injection, and the possibility to do a repeat injection. CONCLUSION: Many disease conditions and the heterogeneities of patients are causes of variation of outcome after cell therapy for osteonecrosis. Predicting therapeutic effectiveness with a calculator allows a good discrimination to target patients who are most likely to benefit from this intervention.


Assuntos
Artroplastia de Quadril , Necrose da Cabeça do Fêmur , Osteonecrose , Masculino , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Inteligência Artificial , Prognóstico , Osteonecrose/terapia , Osteonecrose/cirurgia , Quadril/cirurgia , Necrose da Cabeça do Fêmur/terapia , Necrose da Cabeça do Fêmur/cirurgia , Resultado do Tratamento
16.
Int Orthop ; 47(1): 187-192, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36416898

RESUMO

PURPOSE: Acoustic analysis has recently been applied to cementless total hip arthroplasty (THA). The aim of this study was to develop a machine learning algorithm to predict post-operative subsidence with high accuracy. METHODS: The acoustic parameters of the hammering sounds during a broaching procedure for 62 hips in 55 patients who underwent THAs with cementless taper-wedged stem were analysed. The patient's basic background such as age, sex, height, weight and body mass index, the femoral morphological parameters and the hammering sound characteristics of 24 features of normalised sound pressure (nSP) in 24 frequency ranges were applied to binary classification using a support vector machine using the following models with different features: model A, nSP only; model B, nSP + patients' basic background features; model C, nSP + patients' basic background features + femoral morphological parameters. RESULTS: In 62 hips with 310 hammering sounds, 12 hips (19.4%) showed ≥ 3 mm of post-operative subsidence; hence, 60 hammering sounds were set as positive examples and 250 hammering sounds were set as negative examples. The AUC was very high in all models. The accuracy (AUC/sensitivity/specificity/positive predictive value/negative predictive value/accuracy rate) of each model was as follows: model A, 0.963/0.656/0.996/0.980/0.925/0.934; model B, 0.9866/0.675/1.000/1.000/0.928/0.937 and model C, 0.998/0.750/1.000/1.000/0.950/0.957. CONCLUSION: In this study, we developed a high-accuracy machine learning algorithm for post-operative subsidence using acoustic parameters and additional pre-operative features. Our results represent a step toward the realisation of acoustic monitoring to avoid the complication in cementless THA.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Máquina de Vetores de Suporte , Fêmur/cirurgia , Acústica , Desenho de Prótese , Estudos Retrospectivos
18.
Front Med (Lausanne) ; 9: 978174, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36341255

RESUMO

Introduction: Studies have not sufficiently clarified the differences in citation impact between funded and non-funded clinical research papers. Hence, this study seeks to evaluate the relation between research funding status and clinical research papers' citation impact in different research fields using multiple evaluation indices. Methods: In this cross-sectional bibliometric study, clinical research papers published by core clinical research hospitals in Japan were compared retrospectively in terms of times cited (TC), category normalized citation impact (CNCI), citation percentile (CP), journal impact factor (JIF), the Software to Identify, Manage, and Analyze Scientific Publications (SIGAPS) category, and whether they were the funded clinical research. The association between research funding status or the SIGAPS category and CNCI ≥ 2 was analyzed using logistic regression analysis. Results: 11 core clinical research hospitals published 553 clinical research papers, of which 120 were non-funded and 433 were funded (public institution-funded and industry-funded). The study found that funded clinical research papers (public institution-funded and industry-funded) had significantly higher TC, CNCI, CP, and JIF than non-funded ones [TC: 8 (3-17) vs. 14 (8-31), p < 0.001; CNCI: 0.53 (0.19-0.97) vs. 0.87 (0.45-1.85), p < 0.001; CP: 51.9 (24.48-70.42) vs. 66.7 (40.53-88.01), p < 0.001; JIF: 2.59 (1.90-3.84) vs. 2.93 (2.09-4.20) p = 0.008], while the proportion of A or B rank clinical research papers of the SIGAPS category was not significantly different between the two groups (30.0 vs. 34.9%, p = 0.318). In the logistic regression analysis, having a CNCI ≥ 2 was significantly associated with research funding (public institution-funded and industry-funded) and publication in A or B rank journals of the SIGAPS category [research funding: Estimate 2.169, 95% confidence interval (CI) 1.153-4.083, p = 0.016; SIGAPS category A/B: Estimate 6.126, 95% CI 3.889-9.651, p < 0.001]. Conclusion: Analysis via multiple indicators including CNCI and the SIGAPS category, which allows for a comparison of the papers' citation impact in different research fields, found a positive relation between research funding status and the citation impact of clinical research papers.

20.
Int Orthop ; 46(10): 2205-2212, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35840813

RESUMO

BACKGROUND: Corrosion of stem-cobalt/chromium (Co/Cr) head interface and subsequent systemic Co ion complication have been a clinical concern after total hip arthroplasty (THA). The aim of this study is to investigate correlation between type of femoral head and blood Co ion level. METHODS: One hundred four patients with THA using accolade TMZF and Co/Cr femoral head (32-mm; 55 cases, 36-mm; 20 cases, dual mobility system (DM) with 22.2 or 28-mm inner head; 29 cases) participated in this study, and blood Co ion concentration test was performed in patients a minimum of four years after THA. RESULTS: DM group was significantly older than 32-mm and 36-mm group (DM: 73.9 ± 4.6, 32-mm: 63.3 ± 8.5, 36-mm: 66.8 ± 10.5). The median (interquartile range) blood Co concentration of each group was 32-mm group 0.26 µg/L (0.69), 36-mm group; 0.21 µg/L (0.30); and DM group 0.21 µg/L (0.13). There was a significant difference of Co concentration between DM and 32-mm group (p = 0.023). Abnormal values of the blood Co concentration (> 1 µg/L) were observed in the 32-mm group; 12 cases (21.8%), 36-mm group; 2 cases (10.0%); and DM group; 0 case (0%) (p = 0.018). CONCLUSIONS: Co blood concentration differed among the different sizes of Co/Cr femoral head. THA using DM is a safe option with low risk of complication from cobalt ion if it is used for elderly patients.


Assuntos
Cobalto , Prótese de Quadril , Idoso , Cromo/efeitos adversos , Cobalto/efeitos adversos , Cabeça do Fêmur/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...